Weather compensated controller WDC10B

Weather compensated controllers WDC10B are designed to regulate space heating and domestic hot water heating in individual houses. They allow the regulation of one or two heating circuits, the switching between heat sources and the protection of the return when the storage tank is filled. They are used for heating systems with one or two boilers, a heat pump, a heat storage tank and a solar system.

Use

  • regulating the radiator space heating system,
  • regulating the underfloor heating or cooling system,
  • regulating a convector heating or cooling system,
  • regulating a wall or ceiling heating or cooling system,
  • heating domestic water.


COMPARING THE PERFORMANCE OF CONTROLLERS WDC10B WDC10 WDC20
USE
Controlling a radiator space heating system Yes Yes Yes
Controlling the underfloor heating or cooling system Yes Yes Yes
Controlling a convector heating or cooling system Yes Yes Yes
Controlling a wall or ceiling heating or cooling system Yes Yes Yes
Heating of sanitary water Yes Yes Yes
TECHNICAL CHARACTERISTICS
Number of preset hydraulic schemes 7 17 52
Number of room units 2 2 2
Number of mechanical relays 6 6 7
Number of electronic relays No 1 1
Number of analogue outputs (0÷10 V or PWM) for circulator or power source control 2 2 2
Number of inputs for temperature sensors 7 7 7
BUS-connectivity of WDC controllers to each other and to other Seltron controllers Yes Yes Yes
REGULATING SYSTEMS
Controlling the heating system with radiators Yes Yes Yes
Controlling the underfloor heating or cooling system Yes Yes Yes
Controlling a convector heating or cooling system Yes Yes Yes
Controlling a wall or ceiling heating or cooling system Yes Yes Yes
Regulating the domestic hot water heating system Yes Yes Yes
REGULATING HEATING CIRCUITS
Direct heating circuit Yes Yes Yes
Mixing heating circuit Yes Yes Yes
Direct and mixing circuits No Yes Yes
Two mixing circuits No No Yes
Heating of sanitary water Yes Yes Yes
Switching between direct heating circuit and domestic water heating Yes Yes Yes
Circulation of sanitary water Yes Yes Yes
Automatic switching between heat sources No No Yes
Control of the riser temperature constant Yes Yes Yes
One-step filling of the storage tank No No Yes
REGULATING HEAT SOURCES
Solid fuel boiler Yes Yes Yes
Solid fuel boiler with pellet burner No No Yes
Liquid fuel boiler Yes Yes Yes
Liquid fuel boiler with two-stage burner Yes Yes Yes
Combined boiler No No Yes
Gas-flow boiler No No Yes
Heat pump No No Yes
The repository Yes Yes Yes
Heating with electricity Yes Yes Yes
Solar collectors No Yes Yes
DOMESTIC HOT WATER
With a primary heating source Yes Yes Yes
With heat storage Yes Yes Yes
With a solar system No Yes Yes
USER FUNCTIONS
Space heating or cooling according to a timed programme Yes Yes Yes
Automatic winter/summer switchover Yes Yes Yes
The PARTY function – simple extension of comfort heating Yes Yes Yes
ECO function – activating energy-saving mode Yes Yes Yes
HOLIDAY function – activating holiday mode Yes Yes Yes
Heating of domestic water according to a timed programme Yes Yes Yes
One-off – immediate hot water heating Yes Yes Yes
BOOST function for intensive space heating Yes Yes Yes
Screed drying function Yes Yes Yes
HEATING SYSTEM PROTECTION
Legionella protection (for regulated energy source) Yes Yes Yes
Overheating protection for the storage tank Yes Yes Yes
Boiler overheating protection Yes Yes Yes
Protection against freezing of collectors No Yes Yes
Forced pump switch-on at maximum collector temperature No Yes Yes
Switching off the collectors when the safety temperature is exceeded No Yes Yes
Protecting the solar system when the collectors overheat No Yes Yes
Reverse cooling of the storage tank to the desired temperature No Yes Yes
Periodic start-up of pumps and mixing valves during inactive periods Yes Yes Yes
A COMPREHENSIVE OVERVIEW OF THE HEATING SYSTEM'S OPERATION
Graphical display of temperatures by day for the last week Yes Yes Yes
Detailed display of temperatures for the current day Yes Yes Yes
Notifications of activated safety features and error alerts in
system
Yes Yes Yes
Possibility to simulate sensors and analyse system performance Yes Yes Yes
REMOTE ACCESS
With the addition of a dedicated cable, the controller can be connected to a computer Yes Yes Yes
Connectivity to the SeltronHome platform, allowing remote control via smartphone or tablet Yes Yes Yes
SET-UP AND INSTALLATION
Wizard for easy and fast device start-up Yes Yes Yes
13-language user interface.
Languages: EN, DE, FR, NL, PL, ES, SL, IT, CS, LT, GR, HU, HR
Yes Yes Yes
Setting the operation by selecting the hydraulic scheme Yes Yes Yes
The “Help” button for quick settings assistance Yes Yes Yes
Graphically configurable time programmes Yes Yes Yes
Possibility to simulate system operation Yes Yes Yes
Logging and displaying changes to settings Yes Yes Yes
Ability to retrieve basic settings in case of loss or unwanted changes Yes Yes Yes
Possibility to programme free outputs Yes Yes Yes
Wall or DIN-rail mountable Yes Yes Yes
Easy installation and connection Yes Yes Yes

Key features of the WDC10B controller

  • 7 preset hydraulic schemes,
  • they can be used to regulate new heating systems or to replace existing regulators,
  • heating or cooling rooms according to a timed programme,
  • heating domestic water according to a timetable,
  • regulating storage heating systems,
  • 2 bedroom units can be connected,
  • BOOST function for intensive space heating,
  • 13 language user interface,
  • a wizard to start your device quickly and easily,
  • the ability to simulate sensors and analyse system performance,
  • remote monitoring using SeltronHome.


TECHNICAL DATA WDC10B
Illuminated graphic display Yes
Operating hours counter Yes
Weekly programme hour Yes
Connection voltage 230 V ~ , 50 Hz
Own consumption 2,5 W
Standby power consumption Maximum 0,5 W
Number of entrances 7 x temperature sensor (Pt 1000)
Number of outputs 6 x mechanical
2 x PWM ali analogno 0÷10 V (Y2)
Relay outputs 4 (1) A ~, 230 V ~
Triac output 1 (1) A ~, 230 V ~
Clock power supply Battery CR2032 (Li-Mn) 3 V
Time display accuracy +/- 1 s (24 h) at 20 °C
Degree of protection IP20 to EN 60529
Safety class I according to EN 60730-1
Type of operation 1B to EN 60730-1
Type of temperature sensors Pt1000
Type of operation 3-point PID
Housing material ASA – thermoplastic
Permissible ambient temperature 5 ÷ 40 °C
Storage temperature -20°C to +65°C
Product weight 410 g
Number of pieces per packing unit 6 pieces
Dimensions (W × H × D): 113 x 163 x 48 mm WDC10B measure

Electrical connection WDC10B Electrical connection

Lead Form Test
Step 1 of 5

WANT ADVICE OR A QUOTE?

Here you can ask questions about heating and cooling products or make an enquiry for your project. If you already have technical documents, plans or additional information about your project, you will be able to add them in later steps.

NOTICE

Dear customers!

3. 5. 2025 will be a shop, service and warehouse closed.

Thank you for your understanding.